# Extended Kalman Filter for IMU sensor with 13 calculated states
|
||||
|
||||
The extended Kalman filter (EKF) with 13 states designed to be used with data from common
|
||||
IMU sensor, like MPU9250 or MPU6050. These sensors provide gyroscope, accelerometer
|
||||
and magnetometer data. The sensors have measurement errors, and it's not possible
|
||||
to use them for calculation system attitude.
|
||||
For that the EKF should be used.
|
||||
Current implementation of EKF calculates 13 value to define the system state:
|
||||
1. System attitude [0..3]: quaternion that describes absolute value of system attitude (w, x,y,z)
|
||||
2. Gyroscope sensor errors[4..6]: bias values (x,y,z)
|
||||
3. Magnetometer vector value[7..9]: absolute value of magnetometer sensor (x,y,z)
|
||||
4. Magnetometer vector offset[10..12]: absolute value of magnetometer sensor offset (x,y,z)
|
||||
These values calculated by the EKF and stored to the X vector.
|
||||
Magnetometer value from the sensor has some value and offset. This information needed to calculate system attitude.
|
||||
Magnetometer sensor value = R*Magn_Amplitude + Magn_offset.
|
||||
Where R - rotation matrix from system attitude,
|
||||
Magn_Amplitude - real magnetometer value calculated by the EKF
|
||||
Magn_offset - magnetometer offset value (called deviation)
|
||||
|
||||
|
||||
## How to use EKF
|
||||
The EKF has two main methods: state calculation (Process(...)) and state correction (UpdateRefMeasurement() in our case).
|
||||
The current EKF has one main input value - is a gyroscope (gyro) angular speed. If the gyro has no bias error, then it's enough to call Process(...) method, and EKF
|
||||
will calculate system attitude. But, the gyro has a bias error and that's why, the UpdateRefMeasurement(...) must be called, when reference accelerometer and magnetometer values are available.
|
||||
After the firs start, the EKF will need some time to calculate correct gyro bias and magnetometer deviation. This is a calibration phase.
|
||||
To avoid this phase every time after filter started, it's better to store X vector and P matrix to the non-volatile memory, and restore them after system started.
|
||||
The sequence in this case will be:
|
||||
Init()-> restore X and P values (if exist) -> go to normal process
|
||||
|
||||
|
||||
## Adjustable parameters
|
||||
There two lists of parameters that could be adjusted: R - measurement noise covariance values, and Q - model noise matrix.
|
||||
The R is an array with values for diagonal matrix. Then smaller value R for reference value, then more EKF will trust for this value.
|
||||
In normal case, the R values should be between 0.001 and 1.
|
||||
The Q - is a diagonal (only values in main diagonal are important) noise matrix of state vector. This matrix define how good value in state vector X should be.
|
||||
|
||||
|
||||
|
||||